Sigenergy Hybrid Inverter Guide: Models, Sizes and Sizing for Perth

Quick answer: In Australia the Sigenergy inverter is mainly sold as the SigenStor Energy Controller, a hybrid inverter that sits on top of the battery stack and runs both the solar panels and the battery. Sigenergy’s Australian datasheet lists five single-phase models (5, 6, 8, 10 and 12 kW) and six three-phase models (5, 10, 15, 20, 25 and 30 kW). Single-phase models accept solar arrays of up to twice their rating. In Perth, the right size depends on your array, your peak loads and whether you want backup, because Western Power caps export at 1.5 kW (or 5 kW with an off-take agreement) whichever inverter you choose.

This guide is for anyone comparing Sigenergy inverter sizes or trying to work out what a quote means by “EC 10.0 SP”. It covers the model range, how the inverter fits into the stack, solar input, backup, and how inverter size interacts with Western Power’s 2026 rules. Battery modules, pricing guidance, rebates and the 2025 recall are covered in our Sigenergy SigenStor guide for Perth. Ratings below come from Sigenergy’s Australian datasheets, checked on 20 November 2026.

The Sigenergy inverter types sold in Australia

Sigenergy sells its hybrid inverter in two forms: the Energy Controller that tops a SigenStor battery stack, and a standalone Sigen Hybrid Inverter that mounts on the wall.

  • SigenStor Energy Controller (EC). This is the inverter in a SigenStor battery system. Model names read “SigenStor EC 10.0 SP”, where the number is the size in kilowatts, SP means single-phase and TP means three-phase.
  • Sigen Hybrid Inverter. A wall-mounted hybrid inverter for solar-first installs. Sigenergy’s Australian inverter warranty (dated 24 July 2026) lists Sigen Hybrid SP AU models at 5, 6, 8, 10 and 12 kW and TP AU models at 5, 10, 15, 20, 25 and 30 kW. It also lists a second-generation range: SP2 AU at 3, 5 and 6 kW and TP2 AU at 5, 6, 8, 10 and 12 kW.

The second-generation units are a different design. Sigenergy’s hybrid inverter page describes a 99 mm deep, fanless inverter with two solar inputs (MPPTs). Its datasheet shows that adding Sigen battery modules to an SP2 or TP2 inverter needs a separate battery controller, the SigenStor BC.

One WA detail matters if a battery rebate is part of your plan. On Synergy’s Supported Solutions List dated 6 November 2026, the SigenStor Energy Controllers and complete SigenStor systems have “DER-Storage” entries, which is the category the WA Residential Battery Scheme needs. The standalone Sigen Hybrid 8, 10 and 12 kW SP AU models and the Sigen Hybrid TP AU models appear under “DER-Generator” only. Ask your installer to check the exact model number against the current list before you sign.

Single-phase Sigenergy Energy Controller models

Sigenergy’s Australian Energy Controller datasheet lists five single-phase models from 5 to 12 kW. The two smaller models are fanless and half the weight of the larger three.

ModelAC output (on-grid)Max. solar inputSolar inputs (MPPTs)Backup peak (10 seconds)Cooling and weight
SigenStor EC 5.0 SP4,999 W10,000 W27,500 WNatural convection, 18 kg
SigenStor EC 6.0 SP6,000 W12,000 W29,000 WNatural convection, 18 kg
SigenStor EC 8.0 SP8,000 W16,000 W312,000 WFan (smart air cooling), 36 kg
SigenStor EC 10.0 SP9,999 W20,000 W415,000 WFan (smart air cooling), 36 kg
SigenStor EC 12.0 SP12,000 W24,000 W418,000 WFan (smart air cooling), 36 kg
Source: Sigenergy, Sigen Energy Controller datasheet for Australia, version 20251107. Accessed 20 November 2026.

All five share the same solar input limits: one string per MPPT, 16 A per MPPT, a 50 to 550 V MPPT range and a 600 V maximum DC input voltage. Maximum inverter efficiency is 98.0% for the 5 and 6 kW models and 97.6% for the 8, 10 and 12 kW models. That figure is the inverter’s conversion efficiency, not the round-trip efficiency of the battery.

Synergy’s list and Sigenergy’s warranty also name a 3.0 SP Energy Controller. It is not in the Australian datasheet we checked, so ask for its datasheet if one is quoted.

The Sigenergy 10 kW inverter

The single-phase 10 kW model, the SigenStor EC 10.0 SP, is rated at 9,999 W on-grid. It takes up to 20 kW of solar across four MPPTs and can deliver 15,000 W for 10 seconds in backup mode. It is fan-cooled and weighs 36 kg. There is also a three-phase 10 kW model, the EC 10.0 TP, covered in the next table.

Single-phase 8, 10 and 12 kW controllers with quick-connect AC plugs, sold between 4 March and 18 November 2025, were the subject of a voluntary recall published on 19 November 2025. Sigenergy has since changed the AC connection design. If you are quoted one of these sizes, ask the installer to confirm the unit has the updated connection. The SigenStor guide explains the recall in full.

Three-phase Sigenergy Energy Controller models

The Australian datasheet lists six three-phase models from 5 to 30 kW. They suit homes with a three-phase supply and large loads, and the larger sizes are aimed at big homes and small businesses.

ModelAC output (on-grid)Max. solar inputSolar inputs (MPPTs)Backup peak (10 seconds)
SigenStor EC 5.0 TP5,000 W8,000 W27,500 W
SigenStor EC 10.0 TP9,999 W16,000 W315,000 W
SigenStor EC 15.0 TP15,000 W24,000 W322,500 W
SigenStor EC 20.0 TP20,000 W32,000 W430,000 W
SigenStor EC 25.0 TP25,000 W40,000 W430,000 W
SigenStor EC 30.0 TP29,999 W48,000 W436,000 W
Source: Sigenergy, Sigen Energy Controller datasheet for Australia, version 20251107. Accessed 20 November 2026.

The three-phase models take one string per MPPT at up to 16 A, with a 160 to 1,000 V MPPT range and a 1,100 V maximum DC input. All are fan-cooled. Maximum efficiency runs from 98.1% to 98.4%. Sigenergy also states they support unbalanced output across the three phases, which helps when household loads are spread unevenly. If you are unsure which supply you have, our guide to three-phase power and solar shows how to check.

Synergy’s list also names 6.0, 8.0, 12.0 and 17.0 TP AU controllers. Those sizes are not in the Australian datasheet we checked, so their ratings are not shown here.

How the inverter sits in the battery stack

In a SigenStor, the Energy Controller is the top unit of the stack and the battery modules sit beneath it. One controller takes one to six modules, and it is the single connection point for the solar strings, the battery and the home’s switchboard.

Two things follow from that layout. First, a new solar and battery system needs only one inverter. Second, the inverter rating is not the only limit on power. Each battery module has its own maximum charge and discharge power: 3,000 W for a BAT 6.0 and 4,600 W for a BAT 10.0, according to Sigenergy’s battery datasheet. A 10 kW controller with a single BAT 10.0 module can draw no more than 4,600 W from the battery, however large the inverter is. When the sun is down, the stack needs enough modules to match the power you expect from it.

The optional EV DC charging module also sits in the stack and only works with an Energy Controller. Blackout backup is handled by a separate wall-mounted gateway, covered below.

Solar input and oversizing

The single-phase Energy Controllers accept a solar array of up to twice the inverter’s AC rating, and the three-phase models up to 1.6 times. A 5 kW single-phase controller, for example, is rated for up to 10 kW of panels.

The inverter’s AC rating still caps how much power can go to the house and the grid at any moment. In a battery system, the extra panel capacity is mainly useful for charging the battery and for producing more in the morning, late afternoon and winter, when a smaller array would fall short.

The number of MPPTs matters as much as the wattage. Each MPPT takes one string of panels, so the 5 and 6 kW single-phase models suit roofs with up to two separate panel groups, while the 10 and 12 kW models can handle four. A roof with east, north and west faces needs at least three. For help choosing the array itself, see our guide to what size solar system a Perth home needs.

Backup capability

The Energy Controller has backup output ratings, but running the home through a blackout needs the separate Sigen Energy Gateway installed with it. Sigenergy quotes a 0 ms load-side disruption time, and its datasheet states this applies only when the gateway is used with the controller and battery, and when the controller’s rated power is higher than the load at the time.

That last condition is the one to remember. In a blackout the inverter size is the ceiling on what the house can draw. The 10-second peak ratings in the tables above help with appliances that surge on start-up, but sustained loads have to fit within the controller’s rating and the battery modules’ discharge limits.

Gateway modelSupplyRated currentRated power
Sigen Gateway Home SP AUSingle-phase54.6 A12 kW
Sigen Gateway HomePro SP-F AUSingle-phase100 A22 kW
Sigen Gateway Home TP AUThree-phase45.6 A30 kW
Source: Sigenergy, Sigen Energy Gateway datasheet for Australia, version 20251107, and the gateway page on Sigenergy Australia. Accessed 20 November 2026.

Our guide to battery backup during Perth blackouts explains how long a battery can run typical household loads.

How inverter size interacts with Western Power limits in WA

Under Western Power’s rules for new and upgraded systems from 1 May 2026, a bigger inverter does not buy more export. It buys more power for use inside the home. The export cap is the same for every size.

For Perth metro homes, the limits are:

ConnectionMax. total inverter capacityGeneration limitExport limit, no off-take agreementExport limit, with off-take agreement
Single-phase30 kVA15 kVA1.5 kW5 kW
Three-phase30 kVA8 kVA per phase1.5 kW5 kW (net across all phases)
Source: Western Power, Basic Embedded Generator Connection Technical Requirements (2026), Table 4.1, as set out in our export limits guide. Mandatory from 1 May 2026.

Here is how the Sigenergy range lines up against those figures:

  • Single-phase. All five models, up to the 12 kW (12,000 VA) controller, sit within the 15 kVA generation limit. The old “5 kW inverter” ceiling no longer applies to new or upgraded systems.
  • Three-phase. The generation limit of 8 kVA per phase adds up to 24 kVA. The 5 to 20 kW models are rated within that (the 20 kW model has a maximum output of 22,000 VA). The 25 and 30 kW models are rated above 24 kVA, so on a standard Perth metro connection their output would have to be capped by a site generation limit control.
  • Other inverters count too. Total inverter capacity includes every inverter on the site. If you keep an existing solar inverter and add a SigenStor beside it, both ratings are added together.
  • Above 5 kVA, exports are managed. Western Power’s requirements say systems larger than 5 kVA with an off-take agreement are subject to advanced management and a dynamic operating envelope, so the export limit can move with network conditions.

Outside the metro area and country city centres the limits are lower. A single-phase connection on a small network has a 10 kVA generation limit and a 3 kW maximum export limit. Systems installed or upgraded before 1 May 2026 are not affected unless you upgrade them, and adding a battery counts as an upgrade. The full rules are in our guide to solar export limits in Perth.

How to choose a Sigenergy inverter size for a Perth home

Choose the inverter from your loads and your roof, not from the export limit. These are the questions that settle it:

  1. Single-phase or three-phase supply? This decides which half of the range applies to you.
  2. How many panels, on how many roof faces? The array has to fit within the model’s maximum solar input and its number of MPPTs.
  3. What is your highest simultaneous load? The inverter rating is the most the solar and battery can supply together at one moment. Anything above that comes from the grid. Homes with ducted air conditioning, a pool pump, electric cooking and EV charging can exceed 5 kW at once, and a 5 kW controller would leave the rest to be imported.
  4. Do you want backup, and for which circuits? In a blackout there is no grid to cover the difference, so the inverter and battery have to carry everything you choose to back up.
  5. How many battery modules? The stack’s discharge power should be in step with the inverter. A large controller on one small module gives little benefit after dark.
  6. Are you comfortable with managed exports? Staying at 5 kVA or below keeps a system under the threshold where Western Power’s requirements apply dynamic export management to systems with an off-take agreement.

As a general pattern, a smaller home with modest evening loads is well served by the 5 or 6 kW single-phase models. Larger single-phase homes with air conditioning, a pool or an EV are the cases where 8 to 12 kW earns its place. Self-consumed solar avoids buying power at Synergy’s Home Plan (A1) rate of 33.26c/kWh, while exports earn 10c/kWh between 3pm and 9pm and 2c at other times, so inverter capacity that lets you use more of your own solar and battery energy tends to be worth more than export capacity.

For how Sigenergy sits alongside other inverter types and brands, see our guide to solar inverters in Perth.

Getting a Sigenergy inverter installed with Talk Energy

Talk Energy Solar & Battery supplies and installs Sigenergy inverters and batteries across Perth, using in-house SAA-accredited electricians. We have been in business for more than 7 years, have completed 5,000+ installations and hold WA electrical contractor licence EC15564. We are based at 16 Ogilvie Rd, Mount Pleasant WA 6153.

To have the inverter sized against your supply, roof and loads, see our solar inverter page, request a quote or call 08 6255 5914.

Frequently asked questions

What sizes does the Sigenergy inverter come in?

Sigenergy’s Australian Energy Controller datasheet lists single-phase models at 5, 6, 8, 10 and 12 kW and three-phase models at 5, 10, 15, 20, 25 and 30 kW. The standalone Sigen Hybrid Inverter range adds second-generation models, listed in Sigenergy’s Australian warranty as 3, 5 and 6 kW single-phase and 5, 6, 8, 10 and 12 kW three-phase.

Can I put a 10 kW Sigenergy inverter on a single-phase Perth home?

Under Western Power’s rules for new and upgraded systems from 1 May 2026, a single-phase Perth metro connection has a 15 kVA generation limit, so a 10 kW inverter fits within it. Export is still capped at 1.5 kW, or 5 kW with an off-take agreement. Systems above 5 kVA with an off-take agreement are subject to dynamic export management.

How many solar panels can a Sigenergy inverter take?

The single-phase Energy Controllers accept up to twice their AC rating in solar, so a 5 kW model takes up to 10 kW of panels and a 10 kW model up to 20 kW. Three-phase models accept up to 1.6 times their rating. The array also has to suit the number of MPPTs, which ranges from two to four depending on the model, with one string of panels per MPPT.

Does a Sigenergy inverter work during a blackout?

Only with the separate Sigen Energy Gateway and a battery installed. Sigenergy quotes a 0 ms load-side disruption time when the gateway is fitted and the load is within the inverter’s rating. In a blackout, the inverter size and the battery modules’ discharge power set how much of the house can run at once.

Can I install a Sigenergy inverter now and add the battery later?

Yes. Sigenergy describes its hybrid inverters as battery-ready, and battery modules can be added to a stack later, up to six per controller. The second-generation SP2 and TP2 hybrid inverters need a separate SigenStor BC battery controller to connect the modules. In WA, adding a battery to an existing system counts as an upgrade under Western Power’s rules, and rebate eligibility depends on the exact model being on Synergy’s list at the time.

Is a bigger Sigenergy inverter worth it if export is capped at 5 kW?

It can be, because the export cap only limits what goes to the grid. A larger inverter lets the solar and battery supply more of the home’s own load at once and gives more backup power in a blackout. If your peak loads are modest and backup is not a priority, a 5 or 6 kW model can be enough.