Sigenergy Battery Sizes and Dimensions: Will a SigenStor Fit?
Quick answer: Sigenergy SigenStor battery modules come in four sizes in Australia: BAT 5.0, 6.0, 8.0 and 10.0, with usable energy of 5.2, 6.0, 7.8 and 9.0 kWh. Every module is 767 mm wide and 270 mm high, 260 or 265 mm deep, and weighs 55 to 78 kg. One to six modules stack under one Energy Controller. Sigenergy lists a finished single-phase stack at 850 mm wide and 260 mm deep, standing 640 mm high with one module and 270 mm taller for each module added, up to 1,990 mm with six.
This guide is for anyone checking which SigenStor size to ask for and whether it will physically fit on a garage or outside wall. It covers module capacities, stack configurations, dimensions and weights, and the mounting and location rules that apply in Perth. For features, rebates and the recall history, see our Sigenergy SigenStor guide for Perth homes.
What sizes does the Sigenergy battery come in?
There are four SigenStor battery modules, and all four appear in Sigenergy’s Australian configuration tool. The model number is a label, not the exact capacity, so check the kWh figures.
| Module | Total energy | Usable energy | Max. charge / discharge power | Cell size | Weight |
|---|---|---|---|---|---|
| SigenStor BAT 5.0 | 5.38 kWh | 5.2 kWh | 2.5 kW | 280 Ah | 55 kg |
| SigenStor BAT 6.0 | 6.02 kWh | 6.0 kWh | 3.0 kW | 314 Ah | 62 kg |
| SigenStor BAT 8.0 | 8.06 kWh | 7.8 kWh | 4.0 kW | 280 Ah | 70 kg |
| SigenStor BAT 10.0 | 9.04 kWh | 9.0 kWh | 4.6 kW | 314 Ah | 78 kg |
Two points clear up most of the confusion:
- The “Sigenergy 8 kWh battery” is the BAT 8.0. It stores 8.06 kWh in total and Sigenergy rates 7.8 kWh of that as usable.
- The BAT 10.0 is a 9 kWh module. Its total energy is 9.04 kWh and its usable energy is 9.0 kWh. Two of them give you 18 kWh, not 20.
The BAT 5.0 and 8.0 use 280 Ah cells. The BAT 6.0 and 10.0 are the newer pair, built on 314 Ah cells in the same width and height (Sigenergy BAT 6.0/10.0 datasheet). All four are lithium iron phosphate (LiFePO4). Which modules you are offered depends on stock and on the approved product lists at the time, so confirm the exact model on your quote.
How SigenStor modules stack
One Energy Controller takes a minimum of one battery module and a maximum of six. The controller (the inverter) sits on top and the modules stack underneath it on a base, joined by stacking connectors built into each unit.
Sizes can be mixed in one stack. Sigenergy’s system datasheet lists mixed combinations, for example one BAT 8.0 with one BAT 10.0 for 17.1 kWh of total energy. Each module has its own battery optimiser, which Sigenergy says lets old and new modules work together. That is what makes it practical to start with one or two modules and add more later.
| Modules in the stack | Stack height | BAT 5.0 | BAT 6.0 | BAT 8.0 | BAT 10.0 |
|---|---|---|---|---|---|
| 1 | 640 mm | 5.38 kWh | 6.02 kWh | 8.06 kWh | 9.04 kWh |
| 2 | 910 mm | 10.76 kWh | 12.04 kWh | 16.12 kWh | 18.08 kWh |
| 3 | 1,180 mm | 16.14 kWh | 18.06 kWh | 24.18 kWh | 27.12 kWh |
| 4 | 1,450 mm | 21.52 kWh | 24.08 kWh | 32.24 kWh | 36.16 kWh |
| 5 | 1,720 mm | 26.90 kWh | 30.10 kWh | 40.30 kWh | 45.20 kWh |
| 6 | 1,990 mm | 32.28 kWh | 36.12 kWh | 48.36 kWh | 54.24 kWh |
The largest single stack is six BAT 10.0 modules: 54.24 kWh. Homes that need more than one controller can run more than one SigenStor, which is a design question for your installer.
The optional EV DC charging module is one more layer in the stack. It fits directly under the Energy Controller, adds another 270 mm of height, and reduces the floor-mounted limit to five battery modules. Our guide to EVs, solar and batteries in Perth homes covers when DC charging is worth planning for.
SigenStor dimensions and weight
Each part of a SigenStor is roughly 700 to 770 mm wide, 270 to 300 mm high and about 260 mm deep. The assembled stack, including its base, is listed at 850 mm wide and 260 mm deep. Controller figures below are from the Sigen Energy Controller datasheet.
| Component | Width | Height | Depth | Weight |
|---|---|---|---|---|
| Battery module BAT 5.0 | 767 mm | 270 mm | 260 mm | 55 kg |
| Battery module BAT 8.0 | 767 mm | 270 mm | 260 mm | 70 kg |
| Battery module BAT 6.0 | 767 mm | 270 mm | 265 mm | 62 kg |
| Battery module BAT 10.0 | 767 mm | 270 mm | 265 mm | 78 kg |
| Energy Controller, single phase 5.0 and 6.0 kW | 700 mm | 300 mm | 245 mm | 18 kg |
| Energy Controller, single phase 8.0 to 12.0 kW | 700 mm | 300 mm | 260 mm | 36 kg |
| Energy Controller, three phase 5.0 to 30.0 kW | 700 mm | 300 mm | 260 mm | 36 kg (38 kg for the 30.0 kW) |
For a quick fit check, measure a clear wall section at least 850 mm wide and work out the height from the table above. A typical two-module stack is 910 mm high, about bench height. A four-module stack is 1,450 mm, and a six-module stack is close to two metres.
Weight adds up quickly. Two BAT 10.0 modules and an 8 to 12 kW single-phase controller come to 192 kg before the base and covers (78 + 78 + 36). Six BAT 10.0 modules alone weigh 468 kg. That is why the floor or wall has to be load-bearing, and why Sigenergy’s installation guide calls for a lift when three or more modules are stacked.
Is the SigenStor rated for outdoor installation?
Yes. The battery modules and the Energy Controllers are all rated IP66, and Sigenergy’s installation guide says the equipment can be installed indoors or outdoors. The Sigenergy SigenStor page lists the same rating.
An IP66 rating does not mean full sun is a good idea. The same guide tells installers to avoid direct sunlight, rain and standing water and suggests a sheltered place. The modules have an operating range of -20 to 55 °C, and Sigenergy’s warranty recommends 10 to 30 °C for battery life. In Perth that points to a garage, a carport, or a shaded south or east-facing wall under the eaves, not a west wall in full afternoon sun.
One line in the guide matters for coastal suburbs. Sigenergy says the equipment should be at least 500 m from corrosion sources that can cause salt damage, and it names the seaside as one. If your home is within a few streets of the beach, raise this with your installer before choosing a spot.
Floor or wall mounting
A SigenStor can be floor-standing or wall-mounted, but the wall option is limited to two battery modules. Sigenergy’s installation guide sets these limits:
- Floor mounting: up to six battery modules, or five plus the EV DC module.
- Wall mounting on solid brick or concrete: up to two battery modules, or two plus the EV DC module.
- Wall mounting on a timber wall: up to two battery modules, or one plus the EV DC module.
So any stack of three or more modules stands on the floor, with the controller also fixed back to the wall. The guide adds a few conditions that affect where it can go:
- The base must be flat and able to carry the load. Solid brick, concrete walls and concrete floors are recommended.
- It should not be mounted on a flammable base. If that cannot be avoided, a fire barrier goes between the equipment and the base.
- If the floor is prone to standing water, use a raised waterproof platform or mount it on the wall.
- In a garage, keep it out of the path of vehicles.
- Indoors, the space needs good ventilation, because the equipment gives off heat while it works.
Most Perth garages have a concrete slab and double-brick walls, which suits either method. A two-module stack on the wall keeps the floor clear. Anything bigger needs a patch of level floor about 850 mm wide against a wall.
Where a SigenStor can go on a Perth home
Fitting the space is only half the test. The location also has to comply with AS/NZS 5139, the Australian Standard for battery installations, and your electrician must follow whichever is stricter out of the Standard and Sigenergy’s manual.
The main rules, from regulator guidance on the Standard:
- Not in a habitable room. Bedrooms, living areas, kitchens and studies are out. So are ceiling spaces, wall cavities, the space under stairs and escape routes.
- Clear of openings. The commonly cited clearance is 600 mm to the side of, and 900 mm below, doors, opening windows and vents into habitable rooms.
- Clear of other appliances. Hot water units, air conditioners and similar appliances are kept 600 mm to the side and 900 mm above the battery.
- Protected walls. If the battery is on, or within 300 mm of, a wall with a habitable room behind it, the wall needs a non-combustible barrier. Brick and masonry already count.
- Protected from cars. In a garage, the battery needs a position a vehicle cannot reach, or a fixed bollard.
Put those clearances together with the stack size and the wall space needed grows. An 850 mm stack with an opening window on one side and a door on the other needs about 2,050 mm of wall between them (600 + 850 + 600). The clearance diagrams were updated in the 2025 amendment to the Standard, which WA electrical licence holders have had to follow in full since 19 June 2026, so the final measurement is made on site. Our guide to home battery installation location rules in Perth goes through each rule in detail.
Sigenergy’s manual also has its own spacing diagram for airflow around the stack. Your installer applies that on top of the Standard.
Choosing a SigenStor size
Choose the capacity from your evening and overnight electricity use first, then check that the stack fits. Most Perth homes land between 10 and 15 kWh of usable storage, and our guide to what size battery a Perth home needs shows how to work out your own number from a Synergy bill.
In SigenStor terms, that range looks like this:
- About 9 kWh usable: one BAT 10.0 (640 mm stack).
- About 12 kWh usable: two BAT 6.0 modules (910 mm stack).
- About 15 kWh usable: one BAT 6.0 and one BAT 10.0, or two BAT 8.0 modules at 15.6 kWh (910 mm stack).
- About 18 kWh usable: two BAT 10.0 modules (910 mm stack).
All of those are two modules or fewer, so they can be wall-mounted or floor-standing. Three things are worth weighing before you go bigger:
- Rebates level off. The WA Residential Battery Scheme rebate (up to $1,300 for Synergy customers, up to $3,800 for Horizon Power customers) needs at least 5 kWh of usable capacity and is capped at 10 kWh. The WA Battery Scheme eligibility checklist has the conditions.
- Power, not just energy. Each module has a maximum discharge power, from 2.5 kW for a BAT 5.0 to 4.6 kW for a BAT 10.0. Two modules can deliver roughly twice the power of one, which matters on a hot evening with the air conditioner running.
- You can add later. Leaving headroom on the wall or floor for another 270 mm module costs nothing now and keeps the option open.
Getting a SigenStor sized and installed with Talk Energy
Talk Energy Solar & Battery supplies and installs Sigenergy SigenStor batteries across Perth. Our in-house SAA-accredited electricians (WA electrical contractor licence EC15564) check the wall or floor space, the clearances and the switchboard before the system is designed. We have been operating for 7+ years and have completed 5,000+ installations.
See how we approach solar battery installation in Perth, request a quote, or call 08 6255 5914. We are at 16 Ogilvie Rd, Mount Pleasant WA 6153.
Frequently asked questions
How big is the Sigenergy 8 kWh battery?
The SigenStor BAT 8.0 module is 767 mm wide, 270 mm high and 260 mm deep, and weighs 70 kg. It stores 8.06 kWh in total, with 7.8 kWh rated as usable. With an Energy Controller on top, Sigenergy lists the one-module stack at 850 mm wide, 640 mm high and 260 mm deep.
How much does a SigenStor weigh?
Battery modules weigh 55 kg (BAT 5.0), 62 kg (BAT 6.0), 70 kg (BAT 8.0) or 78 kg (BAT 10.0). The Energy Controller adds 18 kg for the 5 and 6 kW single-phase models and 36 to 38 kg for the larger ones. A two-module BAT 10.0 stack with a 36 kg controller is about 192 kg before the base and covers.
Can a SigenStor be mounted on the wall?
Yes, for smaller stacks. Sigenergy’s installation guide allows wall mounting with up to two battery modules. Stacks of three to six modules have to stand on the floor.
Can a Sigenergy battery be installed outside in Perth?
Yes. The battery modules and Energy Controller are rated IP66 and Sigenergy says the system can be installed indoors or outdoors. Its guide still recommends a sheltered spot out of direct sun, rain and standing water, and the location must meet the AS/NZS 5139 clearance rules.
Can I mix SigenStor battery sizes or add modules later?
Yes. Sigenergy’s system datasheet lists mixed stacks, such as a BAT 8.0 with a BAT 10.0, and each module has its own optimiser so newer and older modules can work together. One Energy Controller takes up to six modules in total.
What is the largest SigenStor on one controller?
Six BAT 10.0 modules, which is 54.24 kWh of total energy. That stack is listed at 850 mm wide, 1,990 mm high and 260 mm deep, and it has to be floor mounted.