Perth home with lights on during a street power outage

Sigenergy Gateway Explained: Blackout Backup for Perth Homes

Quick answer: The Sigenergy Gateway (Sigen Energy Gateway) is a separate wall-mounted switching unit that gives a SigenStor battery its blackout backup. It sits between the grid supply and your home’s circuits, detects an outage, disconnects the house from the grid and lets the battery and solar keep the backed-up circuits running, with a stated 0 ms load-side disruption. The Australian home models are the single-phase Home SP AU (54.6 A, 12 kW), the single-phase HomePro SP-F AU (100 A, 22 kW) and the three-phase Home TP AU (45.6 A, 30 kW). Without a Gateway, a SigenStor does not power the house during a blackout.

This guide is for Perth homeowners who are looking at a SigenStor quote and want to know what the Gateway line item is, which model suits their supply, and whether they need it. It covers switchover, whole-home and partial backup, solar during an outage, generators and what the installation involves. For the battery itself, see our Sigenergy SigenStor guide for Perth homes.

What is a Sigen Gateway?

A Sigen Gateway is the device that turns a SigenStor from a bill-saving battery into a backup power system. Sigenergy describes it as a unit that detects grid outages and transitions the home to backup power, with monitoring and control through the mySigen app.

Inside the enclosure are a grid contactor, a bypass switch, surge protection and a set of labelled circuit breakers. Sigenergy’s installation guides name the connection points:

  • GRID: the incoming supply from the network.
  • INV: one or more Sigenergy inverters (the SigenStor’s Energy Controller).
  • BACKUP: the household circuits that stay on in an outage.
  • Non-backup: circuits that run only while the grid is on (Home SP AU and Home TP AU).
  • SMART-PORT: a generator, or “smart loads” the system can switch off.

When the grid fails, the Gateway’s grid contactor separates the house from the street and the SigenStor supplies the backup circuits. That separation is what allows a battery to keep running safely while the network is down.

Does a SigenStor work in a blackout without the Gateway?

No. Sigenergy’s own SigenStor system datasheet says “the backup function is achieved by the external device: Sigen Energy Gateway”. The SigenStor’s inverter has anti-islanding protection, so without a Gateway it shuts down when the grid drops, the same as ordinary grid-tied solar.

This catches people out, because the datasheet lists an “AC output (backup)” rating for every Energy Controller. That rating is the power the system can deliver through a Gateway. It is not a separate backup outlet on the battery. If blackout protection is one of your reasons for buying, the Gateway has to be on the quote.

Sigenergy Gateway models and current ratings in Australia

Sigenergy lists three home Gateways for Australia: two single-phase models and one three-phase model. The model has to match your supply and the size of your SigenStor inverter.

Gateway modelSupplyNominal current (grid and backup ports)Port circuit breakerNominal powerNon-backup portSize W / H / D, weight
Sigen Gateway Home SP AUSingle phase54.6 A63 A12 kWYes450 / 570 / 197 mm, 22.5 kg
Sigen Gateway HomePro SP-F AUSingle phase100 A125 A22 kWNo450 / 695 / 177 mm, 23.5 kg
Sigen Gateway Home TP AUThree phase45.6 A63 A30 kWYes450 / 570 / 197 mm, 25.5 kg
Source: Sigenergy datasheet “Sigen Energy Gateway for Australia”, version 20251107, accessed 20 November 2026. Sizes and weights are without the decorative cover. All three are wall mounted, rated IP55, with an operating range of -30 to 55 °C.

A few details from that datasheet matter when you compare quotes:

  • Inverter limits. The combined Sigenergy inverter power on one Gateway cannot exceed 12 kW (Home SP AU), 22 kW (HomePro SP-F AU) or 30 kW (Home TP AU).
  • The 100 A model is the whole-home single-phase option. Sigenergy says the HomePro SP-F “fully supports 100 amp single-phase backup power for the entire home”. It has no separate non-backup port.
  • Larger sites. Sigenergy also lists a 60 kW Gateway C60 AU for bigger installations.

For context, a standard Perth metro connection is 63 A on single phase or 32 A per phase on three phase. If you are not sure which you have, our guide to three-phase power and solar explains the difference.

How fast does the Gateway switch over?

Sigenergy states a backup switch disruption time of 0 ms, measured on the load side. In plain terms, the appliances on your backup circuits should not see a gap when the grid drops.

The figure comes with conditions printed in the datasheet footnote. It applies when the Gateway is used with a Sigen Energy Controller and Sigen Battery, and the test assumes the controller’s nominal power is higher than the total power of the backup loads. If the house is drawing more than the system can supply at the moment the grid fails, the result can be different.

So the power rating matters as much as the switch speed. Two limits apply:

  • The inverter. Sigenergy’s Energy Controller datasheet lists nominal backup output equal to the model size: 5 to 12 kW for single-phase controllers and 5 to 30 kW for three-phase, with a higher peak for 10 seconds.
  • The battery modules. Each module has its own maximum charge and discharge power: 2.5 kW for a BAT 5.0, 3 kW for a BAT 6.0, 4 kW for a BAT 8.0 and 4.6 kW for a BAT 10.0. At night, a single module cannot deliver the full output of a large inverter.

Our guide to how long a battery runs a Perth home in a blackout covers typical appliance loads and run times.

Whole-home vs partial backup

The Gateway supports both. Sigenergy’s user manual shows two wiring layouts, and the choice is made when the system is designed, not later in the app.

  • Whole-home backup. Every household circuit sits behind the Gateway’s backup port. Nothing changes for you in an outage, but the whole house is now drawing on one inverter and one battery, so a big load such as ducted air conditioning can use the stored energy quickly or exceed what the system can supply.
  • Partial backup. Chosen circuits (for example fridge, lights, internet and a split system) go on a backup distribution board. Everything else goes on a non-backup board that only runs while the grid is on. The battery lasts longer because heavy loads cannot reach it.

There is a middle path. Sigenergy recommends wiring high-power equipment such as heat pumps, pool heaters and clothes dryers to the smart port as “smart loads”, which the system can cut off when the battery is low. Its example is switching off a heat pump when the battery falls below 20%. For a Perth home with a pool heater or a heat pump hot water unit, that can keep the essentials running longer.

With a Gateway installed, the mySigen app also has a Backup Reserve setting. While the grid is on, the battery stops discharging at the level you set, and that reserve is held for an outage. If you take the WA Residential Battery Scheme rebate you will be in a virtual power plant, so ask how the reserve is treated during VPP events. Our Synergy VPP guide explains the trade-off.

What happens to your solar during a blackout

With a Gateway, solar panels connected to the SigenStor keep working in an outage. Sigenergy describes the changeover as a “seamless transition to PV+ESS power supply”, meaning solar and battery together. In daylight the panels can help run the backed-up circuits and top up the battery, which is what makes a long outage manageable.

Without a Gateway, everything stops. The SigenStor and its solar shut down with the grid and restart when power returns. A full battery makes no difference.

Homes that already have a separate solar inverter need a closer look. Sigenergy’s guidance is that a third-party solar inverter connects to the Gateway’s smart port, not the backup port, and whether it keeps generating in an outage depends on the inverter model and how the system is set up. Raise it at quote if you are adding a battery to existing solar.

Sigenergy’s manual is also clear about the limit: backup lasts only as long as solar and battery can supply the load. If the battery is empty and there is no sun, the backup circuits go off until one of them returns.

Can you connect a generator?

Yes. All three Australian home Gateways list generator support through the smart port, with two-wire start. The generator’s power output is wired to the smart port and a control cable lets the Gateway start and stop it. Sigenergy’s application note says the generator can be started manually, from the app, or automatically using a schedule and a battery charge threshold.

The generator port rating matches the Gateway: 12 kW on the Home SP AU, 22 kW on the HomePro SP-F AU and 30 kW on the Home TP AU. The smart port is shared between a generator and smart loads, so your installer has to design around what you want it to do.

Where the Gateway sits and how it is installed

The Gateway is wired between the incoming grid supply and the circuits it backs up, so it is usually mounted close to the main switchboard and the SigenStor. Installing one is licensed electrical work in Western Australia. It is not a DIY job, and Sigenergy’s guide restricts the work to trained or qualified people.

At a high level, the installation involves:

  1. Design. The electrician checks your supply (single or three phase), main switch rating and switchboard, then decides which circuits go on the backup side.
  2. Mounting. The Gateway goes on a flat, load-bearing, non-flammable wall. Sigenergy recommends solid brick or concrete, and a sheltered spot out of direct sun and rain even though the unit is rated IP55.
  3. Rewiring the supply path. The grid supply, the SigenStor’s AC cable, the backup circuits and any non-backup circuits, smart loads or generator are connected to their own breakers inside the Gateway. On older boards this can mean switchboard work as well.
  4. Communication. A network cable links the Gateway to the SigenStor so the two act as one system.
  5. Commissioning. The installer powers up in sequence, runs the wiring check in the app and sets the backup options.

In WA, battery systems must be installed by a licensed electrical contractor. The work is notifiable, and you should receive an electrical safety certificate when it is finished. The battery stack has its own siting rules under AS/NZS 5139, which we cover in our guide to where a home battery can go in Perth.

When does a Perth home need a Gateway?

You need a Gateway if you want any blackout backup from a SigenStor. You can leave it out only if the battery is purely for storing solar and cutting your Synergy bill, and you accept that the house goes dark with the street.

  • Single-phase home, modest loads: the Home SP AU covers a SigenStor inverter up to 12 kW and has both backup and non-backup ports, so it suits partial backup.
  • Single-phase home wanting the whole house backed up, or running more than 12 kW of Sigenergy inverters: the 100 A HomePro SP-F AU is the model built for that.
  • Three-phase home: the Home TP AU, paired with a three-phase Energy Controller.

What is the difference between SigenStor and SigenStack?

SigenStor is Sigenergy’s home battery system and SigenStack is its larger commercial and industrial one. A SigenStor uses battery modules of roughly 5 to 9 kWh, one to six per controller, and can be floor or wall mounted. Sigenergy’s SigenStack datasheet lists 12.06 kWh modules, floor-standing stacks of up to seven modules and up to 21 modules per system, paired with Sigenergy’s commercial hybrid inverters. Sigenergy says the Gateway range works with both, but a Perth house will almost always be a SigenStor job.

Getting a Sigenergy Gateway installed with Talk Energy

Talk Energy Solar & Battery supplies and installs Sigenergy SigenStor systems across Perth, including the Gateway where you want blackout backup. The work is done by our in-house SAA-accredited electricians under WA electrical contractor licence EC15564. We have been operating for 7+ years and have completed 5,000+ installations.

Tell us which circuits matter most in an outage and we will design the backup around your supply and switchboard. See our solar battery installation page, request a quote, or call 08 6255 5914. We are at 16 Ogilvie Rd, Mount Pleasant WA 6153.

Frequently asked questions

Does a Sigenergy battery work in a blackout without the Gateway?

No. Sigenergy’s SigenStor datasheet states that the backup function is achieved by the external Sigen Energy Gateway. Without one, the SigenStor and its solar shut down when the grid goes off and restart when power returns.

Is the Sigen Gateway included with a SigenStor?

Not automatically. The Gateway is a separate product from the SigenStor’s Energy Controller and battery modules, so it has to be specified. Check that your quote names the Gateway model if you want blackout backup.

Which Sigenergy Gateway suits a single-phase Perth home?

There are two single-phase models in Australia. The Home SP AU is rated 54.6 A and 12 kW with separate backup and non-backup ports, which suits partial backup. The HomePro SP-F AU is rated 100 A and 22 kW and is designed for whole-home backup. Your electrician matches the model to your supply and inverter size.

Will the lights flicker when the power goes out?

Sigenergy states a 0 ms load-side disruption time for the Gateway when it is used with a Sigen Energy Controller and Sigen Battery. The test condition is that the backup loads are within the inverter’s nominal power. If the house is drawing more than the system can supply at that moment, the changeover may not be seamless.

Can I add a generator to a Sigenergy system?

Yes. The Australian Home SP AU, HomePro SP-F AU and Home TP AU Gateways all support a generator on the smart port with two-wire start. The Gateway can start and stop the generator, and Sigenergy’s app lets you set it to manual or automatic operation. It needs to be designed and wired by your installer.

Can I install a Sigenergy Gateway myself?

No. The Gateway is wired into the supply to your home, and in Western Australia battery systems must be installed by a licensed electrical contractor. The work is notifiable and you should receive an electrical safety certificate afterwards.